instru-oil-mechanical-index01

Oil Flowmeter
Mechanical Type

  • For Oil: Kerosene, Diesel, Heavy oil etc,
  • Model Code: FGB, FRO, FRP, FRA,
  • Size: 1 to 6 inch
instru-oil-electronic-index02

Oil Flowmeter Electronic
Type (75series)

  • For Oil: Kerosene, Diesel, Heavy oil etc,
  • Model Code: FGB, FRL, FRY,
  • Size: 1 to 4 inch
instru-oil-intelligent-index01

Electromechanical level alarm NRG 16-50

  • For Oil: Gasoline, Kerosene, Diesel, Heavy oil,
  • Model Code: FRL,
  • Size: 1 to 4 inch
instru-oil-ffl-index01

Level Detector
NRGT26-1

  • For Oil: Gasoline, Kerosene, Diesel, Heavy oil etc,
  • Model Code: FFL,
  • Size: 6 to 14 inch
Pressure Transmitters

Pressure Transmitters
Type DRT

  • Pressure ranges [bar]1 - 60
  • Overpressure safety [bar] 2 - 120
  • Burst pressure [bar] 4 - 200
  • Pressure connection BSP ½"A to DIN 16288
  • Power supply 10 to 30 V DC
  • Output signal 4 to 20 mA, 2-wire system
  • Ambient temperature –10 °C to 80°C
Digital Multicircuit Protector

Digital Multicircuit
Protector

  • Rated input voltage 24 VDC (19.2 to 26.4 VDC)
  • Allowable input current 17.0 A max. nternal voltage drop *1 0.5 VDC max. (at 4.0 A)
  • Output leakage current 10 mA max.
  • Temperature Settingrange: 25 to 80°C
Electromechanical level

Electromechanical level alarm NRG 16-50

  • Service pressure NRG 16-50, 464 psi at 460 °F (32 bar at 238 °C)
  • Thread 1" - 11.5 NPT
  • Screw-in body 1.4404 / F316L
  • Ambient temperature Max. 158 °F (70 °C)
Level Detector NRGT26-1

Level Detector
NRGT26-1

  • End connection: G ¾", PN 40
  • Standard 230 V
  • Optional 115 V DC, 24 V AC/DC
  • Frequency: 50 … 60 Hz
Level Detector LRG 16-41

Level Detector LRG 16-41

  • Service pressure: 32 bar at 238°C
  • Connection Screwed 1" to ISO 228-1
  • Power supply 18 – 36 V DC
  • Resistance thermometer PT 1000
  • Preferred measuring range 100 – 10000 μS/cm at 25°C / 50 – 500 ppm
Temperature Sensor

Temperature Sensor

  • Element type Pt100
  • Class JIS class B
  • Sheath material SUS316 (E52-P[]AY)ASTM316L (E52-P[]B-N, E52-P[]C-N)
  • Sheath outer diameter 3.2 dia., 4.8 dia., 6.4 dia., 8 dia
  • Conductor type 3-conductor system
  • Temperature range -196°C to 450°C
Level Controller

Level Controller NRR 2-52/NRR 2-53

  • Supply voltage 24 V DC +/-20 %
  • Power consumption Max. 5 VA
  • Current input Max. 0.3 A
  • Required external fuse 0.5 A M
  • Input/output Interface for data exchange with the URB 55 visual display and operating unit
Level Switch NRS 1-50

Level Switch NRS 1-50

  • Supply voltage 24 VDC +/– 20%, 0.3 A
  • Power consumption 7 W
  • Storage temperature -4 ° … 158 °F (-20 ° … +70 °C)
  • Site altitude Max. 6560 ft (2000 m)
  • Relative humidity Max. 95%, non-condensing