Instrumentations
![instru-oil-mechanical-index01 instru-oil-mechanical-index01](https://stm-groups.com/wp-content/uploads/2024/01/instru-oil-mechanical-index01.png)
Oil Flowmeter
Mechanical Type
- For Oil: Kerosene, Diesel, Heavy oil etc,
- Model Code: FGB, FRO, FRP, FRA,
- Size: 1 to 6 inch
![instru-oil-electronic-index02 instru-oil-electronic-index02](https://stm-groups.com/wp-content/uploads/2024/01/instru-oil-electronic-index02.png)
Oil Flowmeter Electronic
Type (75series)
- For Oil: Kerosene, Diesel, Heavy oil etc,
- Model Code: FGB, FRL, FRY,
- Size: 1 to 4 inch
![instru-oil-intelligent-index01 instru-oil-intelligent-index01](https://stm-groups.com/wp-content/uploads/2024/01/instru-oil-intelligent-index01.png)
Electromechanical level alarm NRG 16-50
- For Oil: Gasoline, Kerosene, Diesel, Heavy oil,
- Model Code: FRL,
- Size: 1 to 4 inch
![instru-oil-ffl-index01 instru-oil-ffl-index01](https://stm-groups.com/wp-content/uploads/2024/01/instru-oil-ffl-index01.png)
Level Detector
NRGT26-1
- For Oil: Gasoline, Kerosene, Diesel, Heavy oil etc,
- Model Code: FFL,
- Size: 6 to 14 inch
![Pressure Transmitters Pressure Transmitters](https://stm-groups.com/wp-content/uploads/2023/10/Pressure-Transmitters.jpg)
Pressure Transmitters
Type DRT
- Pressure ranges [bar]1 - 60
- Overpressure safety [bar] 2 - 120
- Burst pressure [bar] 4 - 200
- Pressure connection BSP ½"A to DIN 16288
- Power supply 10 to 30 V DC
- Output signal 4 to 20 mA, 2-wire system
- Ambient temperature –10 °C to 80°C
![Digital Multicircuit Protector Digital Multicircuit Protector](https://stm-groups.com/wp-content/uploads/2023/10/Digital-Multicircuit-Protector.jpg)
Digital Multicircuit
Protector
- Rated input voltage 24 VDC (19.2 to 26.4 VDC)
- Allowable input current 17.0 A max. nternal voltage drop *1 0.5 VDC max. (at 4.0 A)
- Output leakage current 10 mA max.
- Temperature Settingrange: 25 to 80°C
![Electromechanical level Electromechanical level](https://stm-groups.com/wp-content/uploads/2023/10/Electromechanical-level.jpg)
Electromechanical level alarm NRG 16-50
- Service pressure NRG 16-50, 464 psi at 460 °F (32 bar at 238 °C)
- Thread 1" - 11.5 NPT
- Screw-in body 1.4404 / F316L
- Ambient temperature Max. 158 °F (70 °C)
![Level Detector NRGT26-1 Level Detector NRGT26-1](https://stm-groups.com/wp-content/uploads/2023/10/Level-Detector-NRGT26-1.jpg)
Level Detector
NRGT26-1
- End connection: G ¾", PN 40
- Standard 230 V
- Optional 115 V DC, 24 V AC/DC
- Frequency: 50 … 60 Hz
![Level Detector LRG 16-41 Level Detector LRG 16-41](https://stm-groups.com/wp-content/uploads/2023/10/Level-Detector-LRG-16-41.jpg)
Level Detector LRG 16-41
- Service pressure: 32 bar at 238°C
- Connection Screwed 1" to ISO 228-1
- Power supply 18 – 36 V DC
- Resistance thermometer PT 1000
- Preferred measuring range 100 – 10000 μS/cm at 25°C / 50 – 500 ppm
![Temperature Sensor Temperature Sensor](https://stm-groups.com/wp-content/uploads/2023/10/Temperature-Sensor.jpg)
Temperature Sensor
- Element type Pt100
- Class JIS class B
- Sheath material SUS316 (E52-P[]AY)ASTM316L (E52-P[]B-N, E52-P[]C-N)
- Sheath outer diameter 3.2 dia., 4.8 dia., 6.4 dia., 8 dia
- Conductor type 3-conductor system
- Temperature range -196°C to 450°C
![Level Controller Level Controller](https://stm-groups.com/wp-content/uploads/2023/10/Level-Controller.jpg)
Level Controller NRR 2-52/NRR 2-53
- Supply voltage 24 V DC +/-20 %
- Power consumption Max. 5 VA
- Current input Max. 0.3 A
- Required external fuse 0.5 A M
- Input/output Interface for data exchange with the URB 55 visual display and operating unit
![Level Switch NRS 1-50 Level Switch NRS 1-50](https://stm-groups.com/wp-content/uploads/2023/10/Level-Switch-NRS-1-50.jpg)
Level Switch NRS 1-50
- Supply voltage 24 VDC +/– 20%, 0.3 A
- Power consumption 7 W
- Storage temperature -4 ° … 158 °F (-20 ° … +70 °C)
- Site altitude Max. 6560 ft (2000 m)
- Relative humidity Max. 95%, non-condensing